diff options
Diffstat (limited to 'active_correction')
| -rw-r--r-- | active_correction/chapter.tex | 35 | 
1 files changed, 29 insertions, 6 deletions
| diff --git a/active_correction/chapter.tex b/active_correction/chapter.tex index e40ff9d..d7b6a4e 100644 --- a/active_correction/chapter.tex +++ b/active_correction/chapter.tex @@ -34,12 +34,35 @@ Some of these strategies have already been implemented, others are partially imp  others are still just ideas.  %
  I hope to show that active correction is a particularly useful strategy in MR-CMDS.  %
 +[SPECTRAL DELAY PARAGRAPH]
 +
 +[POYNTING CORRECTION PARAGRAPH]
 +
 +[EXCITATION POWER CORRECTION PARAGRAPH]
 +
 +[CHOPPING PARAGRAPH]
 +
 +[FIBRILLATION]
 +
  \section{Spectral delay correction}  % ============================================================
 +\begin{figure}
 +  \caption[CAPTION TODO]{
 +    CAPTION TODO: SPECTRAL DELAY CORRECTION FIGURE
 +  }
 +\end{figure}
 +
  \section{Poynting correction}  % ==================================================================
 +\begin{figure}
 +  \caption[CAPTION TODO]{
 +    CAPTION TODO: POYNTING CORRECTION FIGURE
 +  }
 +\end{figure}
 +
  \section{Excitation power correction}  % ==========================================================
 +\clearpage
  \section{Chopping}  % =============================================================================
  \subsection{Scatter}  % ---------------------------------------------------------------------------
 @@ -225,12 +248,6 @@ number of laser shots.  %  Taking twice as many laser shots when dual chopping brings the signal to noise to at least as good
  as the original single chopping.  %
 -Fibrillation is the intentional randomization of excitation phase during an experiment.  %
 -Because the interference term depends on the phase of the excitation field relative to the signal,
 -averaging over many shots with random phase will cause the interference term to approach zero.  %
 -This is a well known strategy for removing unwanted interference terms \cite{SpectorIvanC2015a,
 -  McClainBrianL2004a}.  %
 -
  \subsection{Normalization of dual-chopped self-heterodyned signal}
  %\begin{table}[!htb]
 @@ -280,4 +297,10 @@ Now, substituting in BRAZARD formalism:  \section{Fibrillation}  % =========================================================================
 +Fibrillation is the intentional randomization of excitation phase during an experiment.  %
 +Because the interference term depends on the phase of the excitation field relative to the signal,
 +averaging over many shots with random phase will cause the interference term to approach zero.  %
 +This is a well known strategy for removing unwanted interference terms \cite{SpectorIvanC2015a,
 +  McClainBrianL2004a}.  %
 +
  \section{Conclusions}  % ==========================================================================
\ No newline at end of file | 
