@@ -22,9 +22,8 @@ tunable output frequencies. %
These pulses are directed into a material under investigation. %
The pulses interact with the material, and due to the specific interference between the multiple
fields the material is driven to emit a new pulse: the MR-CMDS signal. %
-This signal may be different in frequency from the input pulses, and it may travel in a new
-direction depending on the exact experiment being performed. %
-% BJT: flip proceeding sentence around
+This signal may have a different frequency and/or direction than the input pulses, depending on the
+exact experiment being performed. %
The MR-CMDS experiment involves tracking the intensity of this output signal as a function of
different properties of the excitation pulses. %
These properties include
@@ -40,12 +39,12 @@ Because MR-CMDS is a family of related-but-separate experiments, each of them a
space, there are special challenges that must be addressed when designing a general-purpose MR-CMDS
instrument. % BJT: be more specific about the challenge at hand
These issues require development of software, hardware, and theory. %
-Five different improvements to MR-CMDS are presented in this dissertation: 1. processing software
-(\autoref{cha:pro}), 2. acquisition software (\autoref{cha:acq}) 3, active artifact correction
-(\autoref{cha:act}), 4. automated OPA calibration (\autoref{cha:opa}), and 5. finite pulse
-accountancy (\autoref{cha:mix}). %
\hyperref[prt:background]{Part I: Background} introduces relevant literature which informs on this
development work. %
+\hyperref[prt:development]{Part II: Development} presents five strategies used to improve MR-CMDS:
+1. processing software (\autoref{cha:pro}), 2. acquisition software (\autoref{cha:acq}) 3, active
+artifact correction (\autoref{cha:act}), 4. automated OPA calibration (\autoref{cha:opa}), and 5.
+finite pulse accountancy (\autoref{cha:mix}). %
Finally, \hyperref[prt:applications]{Part III: Applications} presents three examples where these
-instruments, with these improvements, have been used to address chemical questions in
-semiconductor systems. % \ No newline at end of file
+instruments, with these improvements, have been used to address chemical questions in semiconductor
+systems. % \ No newline at end of file